7 Consistent abnormality (Figure 5.2- E )
Note:
The life counter for the I/D unit, fuser unit, and belt cassette unit is reset automatically when
the unit is replaced.
Consistency Problem Remedy
94.2 mm Image Drum Replace the ID unit.
63.6 mm Developing Roller Replace the ID unit.
57.8 mm Toner Supply Roller Replace the ID unit.
44.0 mm Charge Roller Replace the ID unit.
113.1 mm Fuser Roller (Upper) Replace the fuser unit.
Fuser Roller (Lower) Replace the fuser unit.
57.8 mm Transfer Roller Replace the belt cassette assembly.