Sharp PC-9800T Specifiche Pagina 50: Horizontal connections

50
<Ver. 2.1>
3.4.12 Horizontal connections
While the display is designed to accommodate side-by-side installations, keep in mind that specific installation
configurations may affect ventilation. Observe the following requirements:
1 Installation of up to three units (Horizontal connection)
The following table lists the operating temperature conditions. Use the units under conditions that keep the
outside atmosphere in this range.
Special installation (Horizontal connections)
When the unit must be used at temperatures higher than the above, use forced air-cooling until the temperature onthe
intake side and exhaust side of Units A and B is within the specified range.
Fan
Fan
A
Clearance A between
the wall and a unit
A ≥ 300mm
100 ≤ A < 300
20 ≤ A < 100
A < 20
Operating temperature
conditions
0 to 35 °C
0 to 30 °C
Forced air-cooling is
needed.
Cannnot be used.
If the unit must be used with a clearance of 100 mm or less,
ventilate from under the unit with a fan to forcibly send air in the
direction of the air flow. Use forced air-cooling until the intake
and exhaust temperature values are within the specified range.
Lateral direction
(Total air flow rate:
6 m
3
/min)
Unit A Unit B Unit C
Direct each fan either laterally or
downward.
Downward direction
(Total air flow rate:
6m
3
/min)
Remarks
10 mm
10 mm
Outside atmosphere
+5 °C; however, maxi-
mum temperature is
40 °C
Outside atmosphere
+ 15 °C

File PDF · ·

Stampa

Stampa documento

Condivisione

Domande su Sharp PC-9800T

Non ci sono ancora domande su questo manuale. Fate la prima.

Fai una domanda

Rispondiamo in base al manuale e indichiamo la pagina. La domanda viene pubblicata sul sito dopo il controllo.

Tutte le domande e risposte ›

Prodotti e manuali riguardanti Notebook Sharp PC-9800T