Specifications
85
F25 7.5A HPCO Switch Circuit
F26 5A Power to CAN Connector J98
F4 Remove fuse F4 for units with Australian Bosch or Thermo King Alternators. Install fuse F4 for units with
Prestolite Alternator.
F10 When fuse F10 is installed in the right position the On/Off keys on the HMI turn the unit on and off. When
fuse F10 is installed in the left position the unit will start and run without the HMI control panel.
Electrical Components
Component Current Draw (Amps)
at 12.5 Vdc
Resistance
(Ohms)
Glow Plugs (3) Each 4.3 2.3 ± 0.2
Fuel Solenoid: Pull In Coil
Hold In Coil
35 to 45
0.5
0.2 to 0.3
24 to 29
High Speed (Throttle) Solenoid 3.3 3.8
Damper Solenoid 5.7 2.2
Fuses (Continued)
Fuse Size Function