Sharp R-426H Manuale di Servizio

Navigare online o scaricare Manuale di Servizio per Microonde Sharp R-426H. Sharp R-426H Technical data Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 194
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
FILE NO.
1
Section
2
3
4
5
TECHNICAL DATA
&
SERVICE MANUAL
ASR 425 H / AER 425 SCLE
ASR 425 H / AER 425 SCL3E
ASR 436 H / AER 436 SCL3E
ASR 448 H / AER 448 SCL3E
ASR 425 H / AER 425 SHLE
ASR 425 H / AER 425 SHL3E
ASR 436 H / AER 436 SHL3E
ASR 448 H / AER 448 SHL3E
ADR 425 H / AER 425 SCLE
ADR 425 H / AER 425 SCL3E
ADR 436 H / AER 436 SCL3E
ADR 448 H / AER 448 SCL3E
ADR 425 H / AER 425 SHLE
ADR 425 H / AER 425 SHL3E
ADR 436 H / AER 436 SHL3E
ADR 448 H / AER 448 SHL3E
ACR 425 H / AER 425 SCLE
ACR 425 H / AER 425 SCL3E
ACR 436 H / AER 436 SCL3E
ACR 448 H / AER 448 SCL3E
ACR 425 H / AER 425 SHLE
ACR 425 H / AER 425 SHL3E
ACR 426 H / AER 436 SHL3E
ACR 448 H / AER 448 SHL3E
SPLIT SYSTEM AIR CONDITIONER
OUTDOOR MODEL No. PRODUCT CODE No.
AER 425 SCLE 38 700 7081
AER 425 SCL3E 38 700 7083
AER 436 SCL3E 38 700 7085
AER 448 SCL3E 38 700 7087
AER 425 SHLE 38 700 7082
AER 425 SHL3E 38 700 7084
AER 436 SHL3E 38 700 7086
AER 448 SHL3E 38 700 7088
INDOOR MODEL No. PRODUCT CODE No.
ASR 425 H 38 700 6951
ASR 436 H 38 700 6952
ASR 448 H 38 700 6953
ADR 425 H 38 700 6957
ADR 436 H 38 700 6958
ADR 448 H 38 700 6959
ACR 425 H 38 700 6954
ACR 436 H 38 700 6955
ACR 448 H 38 700 6956
Indoor Unit Outdoor Unit
AER 425 SCLE - AER 425 SCL3E
AER 425 SHLE - AER 425 SHL3E
AER 436 SCL3E - AER 448 SCL3E
AER 436 SHL3E - AER 448 SHL3E
ASR 425 H
ADR 425 H
ACR 425 H
ACR 436 H
ACR 448 H
ASR 426 H
ASR 448 H
ADR 436 H
ADR 448 H
Vedere la pagina 0
1 2 3 4 5 6 ... 193 194

Sommario

Pagina 1 - SERVICE MANUAL

FILE NO.1Section2345TECHNICAL DATA&SERVICE MANUALASR 425 H / AER 425 SCLEASR 425 H / AER 425 SCL3EASR 436 H / AER 436 SCL3EASR 448 H / AER 448 SCL

Pagina 2 - Important

1. Specifications12345I-51-1 Unit Specifications4-Way Air Discharge Semi-concealed TypeMODEL No. Indoor Unit ASR 448 HOutdoor Unit AER 448 SCL3EPOW

Pagina 3 - TABLE OF CONTENTS

1. Specifications112345I - 1141-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ACR 448 H Outdoor Unit : AER 448 SCL3E AE

Pagina 4

1. Specifications12345I - 1151-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ADR 425 H Outdoor Unit : AER

Pagina 5 - Read Me First!

1. Specifications112345I - 1161-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ADR 425 H Outdoor Unit : AE

Pagina 6

1. Specifications12345I - 1171-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ADR 436 H Outdoor Unit : AER

Pagina 7

1. Specifications112345I - 1181-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ADR 448 H Outdoor Unit : A

Pagina 8

2. Processes and functions12345II - 1SM8300802. PROCESSES AND FUNCTIONS2-1 Room Temperature Control ...

Pagina 9

2. Processes and functions112345II - 22-1 Room Temperature ControlThe unit adjusts room temperature by turning the outdoor unit’s compressor ON and OF

Pagina 10 - 1-1 Unit Specifications

2. Processes and functions12345II - 3(B) HeatingChart Summary and Explanations❑ Once the compressor starts, it keeps running for 5 minutes.❑ Once the

Pagina 11

2. Processes and functions112345II - 42-2 Cold Draft Prevention (Heating Cycle)The cold draft prevention function controls indoor fan speed so a stron

Pagina 12

2. Processes and functions12345II - 5Chart Explanations and notes❑ When the fan speed changes, it keeps the speed step for at least 1 minute, even if

Pagina 13

1. Specifications112345I-61-1 Unit Specifications4-Way Air Discharge Semi-concealed TypeMODEL No. Indoor Unit ASR 425 HOutdoor Unit AER 425 SHLEPOWER

Pagina 14

2. Processes and functions112345II - 62-4 Outdoor Fan Speed ControlTo optimize performance in air conditioner, the outdoor fan speed is selected autom

Pagina 15

2. Processes and functions12345II - 72-5 Freeze Prevention (Cooling)Freeze Prevention keeps the indoor heat exchange coil from freezing. Freezing redu

Pagina 16

2. Processes and functions112345II - 82-6 Condensing Temperature Control (Cooling)Condensing temperature is controlled by the outdoor heat exchanger c

Pagina 17

2. Processes and functions12345II - 9Chart Explanations and notes❑ This chart shows how the outdoor fan speed and the electronic refrigerant control v

Pagina 18

2. Processes and functions112345II - 10Chart Summary and Explanations❑ Discharge temperature is sensed by TH8 (discharge gas sensor).❑ When the tempe

Pagina 19

2. Processes and functions12345II - 11Fig. 12Chart summary and Explanations❑ This chart shows how the Operation Mode (COOLING or HEATING) is determine

Pagina 20

2. Processes and functions112345II - 12❑ During the defrost cycle, STANDBY appears on the remote controller.❑ *...Cold Draft Prevention may operate

Pagina 21

2. Processes and functions12345II - 132-11 4-Way Valve, Solenoid ControlThe basic function of the 4-way valve is to direct the refrigerant in the corr

Pagina 22

2. Processes and functions112345II - 14(B) AUTO Control ModeWhen the Compressor has stopped while in AUTO mode, the 4-way valve switches on(heating)

Pagina 23

2. Processes and functions12345II - 152-13 Electronic Expansion Valve❑ This valve allows very precise and smooth control of the amount of refrigerant

Pagina 24

1. Specifications12345I-71-1 Unit Specifications4-Way Air Discharge Semi-concealed TypeMODEL No. Indoor Unit ASR 425 HOutdoor Unit AER 425 SHL3EPOWER

Pagina 25

2. Processes and functions112345II - 162-15 Compressor Current Detection Circuit❑ The Compressor Current Detection Circuit detects the compressor curr

Pagina 26

2. Processes and functions12345II - 172-16 Dehumidifying OperationDehumidifying operation uses the cooling cycle to remove moisture from the air, but

Pagina 27

2. Processes and functions112345II - 18(1) When the unit is stopped, the Auto-flap returns to F5 position.(2) When the airflow direction is set (an op

Pagina 28

2. Processes and functions12345II - 192-18 Controlled by Electronic Expansion ValveThe circulation volume of the refrigerant is controlled by a pulse

Pagina 29

2. Processes and functions112345II - 202-19 Voltage Detection ControlWhen the power voltage falls below 160 V (voltage between N phase and each phase)

Pagina 30 - 1-1Unit Specifications

3. Electrical data12345III - 133. ELECTRICAL DATA3-1 Indoor Units (Electric Wiring Diagram, Schematic Diagram) ... III - 24-Way Air Di

Pagina 31

3. Electrical data112345III - 23-1 Indoor Units111114-Way Air Discharge Semi-concealed Type : ASR 425 H - ASR 436 HASR 448 HTH1TH2TH331212121TH43121D

Pagina 32

3. Electrical data12345III - 3• Schematic DiagramS 854-2-5268-470-00-3 (X)FMI21312121215687313121234512341TR1T20AC230V8P-U28P-U1To Outdoor UnitIndoor

Pagina 33

3. Electrical data112345III - 43-1 Indoor Units22222Ceiling Mounted Type : ACR 425 H - ACR 436 H - ACR 448 HLMConnector9P(WHT)213131433175123456781PSP

Pagina 34

3. Electrical data12345III - 5• Schematic Diagram S 854-2-5268-665-00-0 (TR)FMI213121212131342131321234512341TR1AC230V8P-U28P-U1Indoor CoilIndoor Coil

Pagina 35

1. Specifications112345I-81-1 Unit Specifications4-Way Air Discharge Semi-concealed TypeMODEL No. Indoor Unit ASR 436 HOutdoor Unit AER 436 SHL3EPOWE

Pagina 36

3. Electrical data112345III - 123-1 Indoor Units66666Concealed Duct Type : ADR 425 H - ADR 436 H - ADR 448 HTH1 TH2 TH331TH42121213121Connector9P(WHT)

Pagina 37

3. Electrical data12345III - 133-1 Indoor Units66666Concealed Duct Type : ADR 425 H - ADR 436 H - ADR 448 H• Schematic DiagramS 854-2-5268-843-00-0 (U

Pagina 38

3. Electrical data112345III - 143-2 Outdoor Units11111 AER 425 SCLE - AER 425 SHLE1• Electric Wiring Diagram2 3 4 NLTH6TH7TH82121213163PH3131357913113

Pagina 39

3. Electrical data12345III - 153-2 Outdoor Units11111 AER 425 SCLE - AER 425 SHLE• Schematic DiagramFMO21311221212131TRAC 230VAC 14VTH8TH7TH62P-22P-13

Pagina 40 - (B) Outdoor Unit

3. Electrical data112345III - 163-2 Outdoor Units22222 AER 425 SCL3E - AER 425 SHL3E1• Electric Wiring Diagram2 3 4 5 67 8TH6TH7TH82121213163PH3131 35

Pagina 41

3. Electrical data12345III - 173-2 Outdoor Units22222 AER 425 SCL3E - AER 425 SHL3E• Schematic DiagramFMO21311221212131TRAC 230VAC 14VTH8TH7TH62P-22P-

Pagina 42

3. Electrical data112345III - 183-2 Outdoor Units33333 AER 436 SCL3E - AER 436 SHL3E - AER 448 SCL3E - AER 448 SHL3E1• Electric Wiring Diagram2 3 45 6

Pagina 43

3. Electrical data12345III - 193-2 Outdoor Units33333 AER 436 SCL3E - AER 436 SHL3E - AER 448 SCL3E - AER 448 SHL3E• Schematic DiagramFMO2213112212121

Pagina 44

4. Service procedures12345IV-14. SERVICE PROCEDURES4-1 Troubleshooting ...

Pagina 45

4. Service procedures112345IV - 24-1 TroubleshootingThis section explains:This unit is made to be trouble free, and not need much service. However, w

Pagina 46

1. Specifications12345I-91-1 Unit Specifications4-Way Air Discharge Semi-concealed TypeMODEL No. Indoor Unit ASR 448 HOutdoor Unit AER 448 SHL3EPOWER

Pagina 47 - Ceiling Mounted Type

4. Service procedures12345IV-3(1)-1 Check before and after Troubleshooting (AER 425 SHLE)Many problems may happen because of wiring or power supply pr

Pagina 48 - Concealed Duct Type

4. Service procedures112345IV - 4 Power Supply: 50 Hz, 3-phase, 380-400-415 V12U1U2R1R2R3123123124L1L2L3NIndoor UnitInter-unitpower wiring(Line v

Pagina 49 - Outdoor Unit

4. Service procedures12345IV-5(2) General Troubleshooting Flow Chart: Diagnosis and RemedyWhen you have found a major problem, such as refrigerant not

Pagina 50

4. Service procedures112345IV - 6(B) HeatingPoor heatingIs setting temp.suitable ?Change the setting temp.Is heating loadtoo large ?Review heating loa

Pagina 51

4. Service procedures12345IV-7(3) Meanings of alarm messagesIf an error occurred in the air conditioner, the error condition is presented by indicatin

Pagina 52

4. Service procedures112345IV - 8Wired remotecontrollerdisplayWireless remotecontrollerdisplayPossible causes of troubles• Thermistor failureOperation

Pagina 53 - 1-4 Dimensional Data

4. Service procedures12345IV-9(4) LED Indication on the Outdoor Unit’s P.C.B. Ass’yIf something goes wrong with the outdoor unit, LED lamps on the ou

Pagina 54

4. Service procedures112345IV - 10(5) Symptoms and parts to inspect1) Symptom: LCD on the remote controller does not display and remote controller doe

Pagina 55

4. Service procedures12345IV - 112) Symptom: LCD on the remote controller displays “CHECK E01”.(Unusual communication between remote controller and in

Pagina 56

4. Service procedures112345IV - 124) Symptom: LCD on the remote controller is displaying “CHECK E04”. (Unusualcommunication between the indoor and ou

Pagina 57

1. Specifications112345I-101-1 Unit SpecificationsCeiling Mounted TypeMODEL No. Indoor Unit ACR 425 HOutdoor Unit AER 425 SCLEPOWER SOURCE 220 - 230 -

Pagina 58

4. Service procedures12345IV - 136) Symptom: LCD on the remote controller is displaying “CHECK E06”. (Unusualcommunication between the indoor and out

Pagina 59

4. Service procedures112345IV - 149) Symptom: LCD on the remote controller displays “CHECK P01”. (Indoor fanprotection thermostat operation warning)N

Pagina 60

4. Service procedures12345IV - 1510) Symptom: LCD on the remote controller displays “CHECK P02”. (Compressor /outdoor fan protection thermostat opera

Pagina 61 - 1-5 Refrigerant Flow Diagram

4. Service procedures112345IV - 1611) Symptoms: LCD on the remote controller displays “CHECK P03”.(Alarm for unusual discharge temp. of compressor)12)

Pagina 62

4. Service procedures12345IV - 1713) Symptom: LCD on the remote controller displays “CHECK P05”. (Negative phasedetection operation warning)YesNoNoNo

Pagina 63

4. Service procedures112345IV - 1815) Symptom: LCD on the remote controller displays “CHECK E16”.NoNoNoYesYes0647_M_SStartRepair the wiring.When the g

Pagina 64 - 1-6 Operating Range

4. Service procedures12345IV - 1917) Symptom: LCD on the remote controller displays “CHECK H01, H02, H03”. (PCcompressor current detection)* Please c

Pagina 65 - 1-7 Cooling Capacity

4. Service procedures112345IV - 20(6) Procedures When a Specific Component Does Not Work1) Indoor fan does not operate.3) Flap does not operate, when

Pagina 66

4. Service procedures12345IV - 214) Compressor motor does not operate.5) Outdoor fan does not operate.NoYesNoYesIs fan motor capacitor normal ?NoIs th

Pagina 67

4. Service procedures112345IV - 22(7) Service Functions of Remote ControllerFrom the remote controller you can control both the operation and settings

Pagina 68

1. Specifications12345I-111-1 Unit SpecificationsCeiling Mounted TypeMODEL No. Indoor Unit ACR 425 HOutdoor Unit AER 425 SCL3EPOWER SOURCE 380 - 400 -

Pagina 69

4. Service procedures12345IV - 23(B) Use the test run procedure❏ The purpose of the test run function is to let you control the operation of the unitd

Pagina 70

4. Service procedures112345IV - 24(C) Check the sensor temperature readingsThe air conditioner has thermo sensors which are used to control the unit.❏

Pagina 71

4. Service procedures12345IV - 25Refer to the table below for the relationship between the sensor address and the locationof the sensor.In case there

Pagina 72

4. Service procedures112345IV - 26This picture shows the service check display.For example, if the last four alarm messages were, in order of occurren

Pagina 73

4. Service procedures12345IV - 27Never press CL (clear) button unless you want to erase the accessed data in memory.Follow the procedure below only wh

Pagina 74

4. Service procedures112345IV - 28(F) Execute the auto. address operation❏ Auto. address operation is executed by pressing the A. ADD (S1) button of o

Pagina 75

4. Service procedures12345IV - 29(G) Confirm and change the indoor unit address❏ The purpose of the above function is to let you confirm the indoor un

Pagina 76

4. Service procedures112345IV - 30e Set the required new indoor unit’s No. by pressing the , ( ) button.f Press the SET button.UNIT No, SET DATA (0

Pagina 77 - ● Heating Capacity

4. Service procedures12345IV - 31(H) Change the shift temperature in heating mode❏ If the indoor unit is installed at high location (ex. ceiling level

Pagina 78 - 1-8 Noise Criterion Curves

4. Service procedures112345IV - 32( I ) Set the indoor unit address❏ This function is usable if the auto. address operation is not available.Indoor un

Pagina 79

1. Specifications112345I-121-1 Unit SpecificationsCeiling Mounted TypeMODEL No. Indoor Unit ACR 436 HOutdoor Unit AER 436 SCL3EPOWER SOURCE 380 - 400

Pagina 80

4. Service procedures12345IV - 33d Set the No. of R. C. which you want to set with , ( ) button.e Press the SET button.UNIT No., CODE No. 12,SETTIN

Pagina 81

4. Service procedures112345IV - 34i Select the code No. 14 to set group setting with the , (SET TEMP) button.jSet the No. of group setting as shown

Pagina 82 - Limit line

4. Service procedures12345IV - 35(J) Change the period of the filter timer❏ If the period of filter timer is not suitable (for example in case of dirt

Pagina 83 - 1-10 Air throw Distance Chart

4. Service procedures112345IV - 364-2 Checking the Electrical Components(1) Measurement of InsulationResistance• The insulation is in good condition i

Pagina 84

4. Service procedures12345IV - 37(2) Measurement of InsulationResistance for Electrical parts• Disconnect the connector of the desiredelectric part fr

Pagina 85 - Tubing Length

4. Service procedures112345IV - 38(3) Checking the Protective Devices• Disconnect the connector, which consists of P (plug) and S (socket) whenyou wan

Pagina 86

4. Service procedures12345IV - 39(4) Checking the Electrical Parts1 Power transformer (TR1) ... Indoor unit *Measure the coil resistance

Pagina 87

4. Service procedures112345IV - 406 Solenoid coil of the electronic refrigerant *Measure the coil resistance.control valve (ERCV) ………… Indoor unit•Mea

Pagina 88 - 0426_C_I

4. Service procedures12345IV - 410 Fuse on indoor and outdoor P.C.B. Ass’y …. Both in indoor and outdoor unit*Check the continuity.• Remove the P.C.B.

Pagina 89 - 8 - ø6 hole

4. Service procedures112345IV - 42(5) Sensor and Solenoid Layout DiagramIndoor Unit• ASR 425 HTH3 (E2), (BLK)TH2 (E1), (RED)Electronic expansion valve

Pagina 90 - Electrical Wiring

1. Specifications12345I-131-1 Unit SpecificationsCeiling Mounted TypeMODEL No. Indoor Unit ACR 448 HOutdoor Unit AER 448 SCL3EPOWER SOURCE 380 - 400 -

Pagina 91 - 0511_M_I

4. Service procedures12345IV - 43• ACR 436 H - ACR 448 HTH3 (E2), (BLK)TH4 (E3), (BRN)1219_THS_ITH2 (E1), (RED)Electronic expansion valveTH4 (E3), (BR

Pagina 92

4. Service procedures112345IV - 44SM830080Heat exchTH5 (Discharge Air)1264_C_ITH3 (E2), (BLK)TH2 (E1), (RED)Electronic expansion valveTH4 (E3), (BRN)1

Pagina 93 - ■ Electrical Characteristics

4. Service procedures12345IV - 45• AER 436 SHL3E0585_C_STH6 (C1), (BLK)TH7 (C2), (RED)TH6, 7, 8CMCHTH8 (GRN)( Discharge gas)63PH20S0584_C_S0583_C_STH6

Pagina 94

4. Service procedures112345IV - 460585_C_STH6 (C1), (BLK)TH7 (C2), (RED)TH6, 7, 8CMCHTH8 (GRN)( Discharge gas)63PH20S0586_C_SOutdoor Units• AER 448 SH

Pagina 95

4. Service procedures12345IV - 47(1) Room temp. sensor : TH1 (KTEC-35)TH5 (KTEC-35)(2) Indoor heat exch.coil sensor : TH2(E1), TH3(E2),TH4(E3)Outdoor

Pagina 96

4. Service procedures112345IV - 48(7) P.C.B. Setting● Setting of outdoor control PCB(A) Standard control (single outdoor unit)In case of single outdoo

Pagina 97

4. Service procedures12345IV - 49(8) R.C. Address Setting MethodOutdoor unit R.C. address setting methodIn case of group control or central control, s

Pagina 98

4. Service procedures112345IV - 50(9) Automatic Address Setting Method— For group control and central control withmultiple outdoor units —Carry out au

Pagina 99

4. Service procedures12345IV - 51(11) Items to Check Prior to Test Run(1) Turn on the power supply switch more than 5 hours before in order to charge

Pagina 100 - Electrical Characteristics

4. Service procedures112345IV - 52(12) Test Run Procedure1) One of CN4 of all linked outdoor units shold be short.2) In case of using system controlle

Pagina 101

1. Specifications112345I-141-1 Unit SpecificationsCeiling Mounted TypeMODEL No. Indoor Unit ACR 425 HOutdoor Unit AER 425 SHLEPOWER SOURCE 220 - 230 -

Pagina 102

5. Appendix12345V-155. APPENDIX5-1 P.C.B. ... V - 2

Pagina 103

5. Appendix112345V-25-1 P.C.B.Outdoor Unit Control P.C.B. :AER 425 SCL3E - AER 436 SCL3E - AER 448 SCL3EAER 425 SHL3E - AER 436 SHL3E - AER 448 SHL3EC

Pagina 104

5. Appendix12345V-35-1 P.C.B.Outdoor Unit Control P.C.B. : AER 425 SCLE - AER 425 SHLECR-CR253GHL5JP11JP8JP7JP2JP11578_C_SCN1 : VCCCN26 (WHT)CN27S2 (B

Pagina 105 - SM830080

5. Appendix112345V-4When replacing the indoor unit P.C.B. for service, remove the *E2P-ROM of the original P.C.B. then attach itto the new P.C.B. sinc

Pagina 106 - 2-1 Room Temperature Control

• The specifications, designs, and information in this brochure are subject to change without notice.

Pagina 107 - SET SPEED

Please Read Before StartingThis air conditioning system meets strict safety andoperating standards. As the installer or service person, itis an import

Pagina 108 - 0673_X_S

1. Specifications12345I-151-1 Unit SpecificationsCeiling Mounted TypeDATA SUBJECT TO CHANGE WITHOUT NOTICE.Cooling:Rating conditions (*): Indoor air t

Pagina 109 - Chart Explanations and notes

1. Specifications112345I-161-1 Unit SpecificationsCeiling Mounted TypeDATA SUBJECT TO CHANGE WITHOUT NOTICE.Cooling:Rating conditions (*): Indoor air

Pagina 110 - 2-4 Outdoor Fan Speed Control

1. Specifications12345I-171-1 Unit SpecificationsCeiling Mounted TypeDATA SUBJECT TO CHANGE WITHOUT NOTICE.Cooling:Rating conditions (*): Indoor air t

Pagina 111

1. Specifications112345I-261-1 Unit SpecificationsConcealed Duct TypeMODEL No. Indoor Unit ADR 425 HOutdoor Unit AER 425 SCLEPOWER SOURCE 220 - 230 -

Pagina 112 - 2. Processes and functions

1. Specifications12345I-271-1 Unit SpecificationsConcealed Duct TypeMODEL No. Indoor Unit ADR 425 HOutdoor Unit AER 425 SCL3EPOWER SOURCE 380 - 400 -

Pagina 113

1. Specifications112345I-281-1 Unit SpecificationsConcealed Duct TypeDATA SUBJECT TO CHANGE WITHOUT NOTICE.Cooling:Rating conditions (*): Indoor air t

Pagina 114 - 1566_M_S

1. Specifications12345I-291-1 Unit SpecificationsConcealed Duct TypeDATA SUBJECT TO CHANGE WITHOUT NOTICE.Cooling:Rating conditions (*): Indoor air te

Pagina 115

1. Specifications112345I-301-1 Unit SpecificationsConcealed Duct TypeMODEL No. Indoor Unit ADR 425 HOutdoor Unit AER 425 SHLEPOWER SOURCE 220 - 230 -

Pagina 116 - Fig. 13

1. Specifications12345I-311-1 Unit SpecificationsConcealed Duct TypeMODEL No. Indoor Unit ADR 425 HOutdoor Unit AER 425 HL3EPOWER SOURCE 380 - 400 - 4

Pagina 117 - 0443_M_S

1. Specifications112345I-321-1 Unit SpecificationsConcealed Duct TypeMODEL No. Indoor Unit ADR 436 HOutdoor Unit AER 436 SHL3EPOWER SOURCE 380 - 400 -

Pagina 118 - (B) AUTO Control Mode

iiWHO SHOULD USE THIS MANUALThis service manual is made to assist the service technician apply his knowledge andtraining to this model air conditioner

Pagina 119 - (A) Cooling

1. Specifications12345I-33SM80081-1Unit SpecificationsConcealed Duct TypeMODEL No. Indoor Unit ADR 448 HOutdoor Unit AER 448 SHL3EPOWER SOURCE 380 - 4

Pagina 120 - 0447_M_S

1. Specifications112345I-341-2 Major Component Specifications(A) Indoor Units : 4-Way Air Discharge Semi-concealed TypeMODEL No. ASR 425 HSource 220 -

Pagina 121 - 2-16 Dehumidifying Operation

1. Specifications12345I-351-2 Major Component Specifications(A) Indoor Units : 4-Way Air Discharge Semi-concealed TypeMODEL No. ASR 436 HSource 220 -

Pagina 122 - Ceiling-Mounted Type)

1. Specifications112345I-361-2 Major Component Specifications(A) Indoor Units : 4-Way Air Discharge Semi-concealed TypeMODEL No. ASR 448 HSource 220 -

Pagina 123 - 0451_M_S

1. Specifications12345I-371-2 Major Component Specifications(A) Indoor Units : Ceiling Mounted TypeMODEL No. ACR 425 HSource 220 - 230 - 240 V / 1 pha

Pagina 124

1. Specifications112345I-381-2 Major Component Specifications(A) Indoor Units : Ceiling Mounted TypeMODEL No. ACR 436 HSource 220 - 230 - 240 V / 1 ph

Pagina 125

1. Specifications12345I-391-2 Major Component Specifications(A) Indoor Units : Ceiling Mounted TypeMODEL No. ACR 448 HSource 220 - 230 - 240 V / 1 pha

Pagina 126 - • Electric Wiring Diagram

1. Specifications12345I-431-2 Major Component Specifications(A) Indoor Units : Concealed Duct TypeMODEL No. ADR 425 HSource 220 - 230 - 240 V / 1 pha

Pagina 127 - • Schematic Diagram

1. Specifications112345I-441-2 Major Component Specifications(A) Indoor Units : Concealed Duct TypeMODEL No. ADR 436 HSource 220 - 230 - 240 V / 1 pha

Pagina 128

1. Specifications12345I-451-2 Major Component Specifications(A) Indoor Units : Concealed Duct TypeMODEL No. ADR 448 HSource 220 - 230 - 240 V / 1 phas

Pagina 129

iii2-7 Overload Protection (Heating) ...II - 92-8 Discharge Temperature Control (Cool

Pagina 130

1. Specifications112345I-461-2 Major Component Specifications(B) Outdoor UnitMODEL No. AER 425 SCLESource 220 - 230 - 240 V / 1 phase / 50 HzControlle

Pagina 131

1. Specifications12345I-471-2 Major Component Specifications(B) Outdoor UnitMODEL No. AER 425 SHLESource 220 - 230 - 240 V / 1 phase / 50 HzController

Pagina 132

1. Specifications112345I-481-2 Major Component Specifications(B) Outdoor UnitMODEL No. AER 425 SCL3ESource 380 - 400 - 415 V / 3 phase / 50 HzControll

Pagina 133

1. Specifications12345I-491-2 Major Component Specifications(B) Outdoor UnitMODEL No. AER 425 SHL3ESource 380 - 400 - 415 V / 3 phase / 50 HzControlle

Pagina 134

1. Specifications112345I-501-2 Major Component Specifications(B) Outdoor UnitMODEL No. AER 436 SCL3E AER 448 SCL3ESource 380 - 400 -

Pagina 135

1. Specifications12345I-511-2 Major Component Specifications(B) Outdoor UnitMODEL No. AER 436 SHL3E AER 448 SHL3ESource 380 - 400

Pagina 136

1. Specifications112345I-521-3 Other Component Specifications4-Way Air Discharge Semi-concealed TypeMODEL NO. Indoor Unit ASR 425 ~ 448HPower Transfo

Pagina 137

1. Specifications12345I-531-3 Other Component SpecificationsCeiling Mounted TypeMODEL NO. Indoor Unit ACR 425 ~ 448HPower Transformer ATR-II215TBRated

Pagina 138

1. Specifications12345I-551-3 Other Component SpecificationsConcealed Duct TypeMODEL NO. Indoor Unit ADR 425 ~ 448 HPower Transformer ATR-II215TBRated

Pagina 139 - This section explains:

1. Specifications112345I-561-3 Other Component SpecificationsOutdoor UnitMODEL NO. Outdoor Unit AER 425 SCLE - AER 425 SCL3EPower Transformer ATR - I6

Pagina 140 - 0500_M_I

ivWHAT IS IN THIS MANUALIntroduction: Read Me First!This manual will help you understand and service the air conditioner. To help you find the informa

Pagina 141 - 0499_M_I

1. Specifications12345I-571-3 Other Component SpecificationsOutdoor UnitMODEL NO. Outdoor Unit AER 425 SHLE - AER 425 SHL3EPower Transformer ATR - I65

Pagina 142 - 0458_M_I

1. Specifications112345I-581-3 Other Component SpecificationsOutdoor UnitMODEL NO. Outdoor Unit AER 436 SCL3E - AER 448 SCL3EPower Transformer ATR - I

Pagina 143 - (B) Heating

1. Specifications12345I-591-3 Other Component SpecificationsOutdoor UnitMODEL NO. Outdoor Unit AER 436 SHL3E AE

Pagina 144

1. Specifications112345I-60860100760500500298 30205165121248860820 (Ceiling opening)820 (Ceiling opening)61730 (Suspention bolt pitch)Panel center590

Pagina 145

1. Specifications12345I-6111501050790500328302181258601110 (Ceiling opening)820 (Ceiling opening)611020 (Suspention bolt pitch)Panel center590 (Suspen

Pagina 146 - 0654_C_I

1. Specifications112345I-62Drain connectionDrain connection for left sideRefrigerant liquid line (ø9.52)Refrigerant gas line (18, 25 type: ø15.88 / 36

Pagina 147

1. Specifications12345I-631-4 Dimensional Data(A) Indoor Units : Concealed Duct Type25 TypeRefrigerant liquid line ø9.52 (narrow tube)(Use the tube co

Pagina 148

1. Specifications112345I-641-4 Dimensional Data(A) Indoor Units : Concealed Duct Type36, 48 TypeRefrigerant liquid line ø9.52 (narrow tube)Refrigerant

Pagina 149

1. Specifications12345I-651-4 Dimensional Data7 Flange for the air intake duct (Field supply): For Concealed Duct Type2-ø3.3101831FGHGF9EDB (O.D.)A25(

Pagina 150 - 1903_M_I

1. Specifications12345I-67735280307940Dimension : mmHole for anchor bolt (4-ø13)Refrigerant tube joint (narrow tube) Flare connection 1/4 in (6.35 mm)

Pagina 151 - 0340_M_I

1. Specifications12345I-11. SPECIFICATIONS1-1 Unit Specifications ... I

Pagina 152

1. Specifications112345I-681-4 Dimensional Data(B) Outdoor Units : AER 436 SCL3E - AER 436 SHL3EAER 448 SCL3E - AER 448 SHL3E1235580607940Dimension :

Pagina 153

1. Specifications12345I-69HPHighpressureswitchCompressorAccumulatorAccumulatorECPHeat exchangerECPHeat exchangerDistributorElectronicref.controlvalveS

Pagina 154

1. Specifications112345I-70HPHigh pressureswitchCompressorAccumulatorECPHeat exchangerECPHeat exchangerDistributorElectronicref.controlvalveStrainerLi

Pagina 155

1. Specifications12345I-71HPHighpressureswitchCompressorAccumulatorAccumulatorECPHeat exchanger4-way valveECPHeat exchangerDistributorElectronicref.co

Pagina 156 - 0460_M_I

1. Specifications112345I-72HPLPHigh pressureswitchCompressorLow pressure switchAccumulatorECPHeat exchanger4-way valveECPHeat exchangerDistributorElec

Pagina 157 - 0652_M_S

1. Specifications12345I-731-7 Cooling CapacityIndoor Unit : ASR 425 H Outdoor Unit : AER 425 SCLE AER 425 SHLETC : Total Cooling

Pagina 158

1. Specifications112345I-74TC : Total Cooling Capacity (kW)SHC : Sensible Heat Capacity (kW)CI : Compressor Input (kW)Rating conditions are: Outdoor A

Pagina 159 - 0354_M_I

1. Specifications12345I-751-7 Cooling CapacityIndoor Unit : ASR 436 H Outdoor Unit : AER 436 SCL3EAER 436 SHL3ETC : Total Cooling Capacity

Pagina 160 - ON / OFF operation

1. Specifications112345I-76TC : Total Cooling Capacity (kW)SHC : Sensible Heat Capacity (kW)CI : Compressor Input (kW)Rating conditions are: Outdoor A

Pagina 161 - 0356_M_I

1. Specifications12345I-77TC : Total Cooling Capacity (kW)SHC : Sensible Heat Capacity (kW)CI : Compressor Input (kW)Rating conditions are: Outdoor Am

Pagina 162

1. Specifications112345I-21-1 Unit Specifications4-Way Air Discharge Semi-concealed TypeMODEL No. Indoor Unit

Pagina 163

1. Specifications112345I-78TC : Total Cooling Capacity (kW)SHC : Sensible Heat Capacity (kW)CI : Compressor Input (kW)Rating conditions are: Outdoor A

Pagina 164

1. Specifications12345I-791-7 Cooling CapacityIndoor Unit : ACR 436 H Outdoor Unit : AER 436 SCL3EAER 436 SHL3ETC : Total Cooling

Pagina 165 - Set CODE No. A1 with

1. Specifications112345I-80TC : Total Cooling Capacity (kW)SHC : Sensible Heat Capacity (kW)CI : Compressor Input (kW)Rating conditions are: Outdoor A

Pagina 166 - 0362_M_I

1. Specifications12345I-811-7 Cooling CapacityIndoor Unit : ADR 425 H Outdoor Unit : AER 425 SCLEAER 425 SHLETC : Total Cooling Capacity

Pagina 167

1. Specifications112345I-821-7 Cooling CapacityIndoor Unit : ADR 425 H Outdoor Unit : AER 425 SCL3EAER 425 SHL3ETC : Total Cooling Capacity (k

Pagina 168 - (SET TEMP) button

1. Specifications12345I-831-7 Cooling CapacityIndoor Unit : ADR 436 H Outdoor Unit : AER 436 SCL3EAER 436 SHL3ETC : Total Cooling

Pagina 169 - 0368_M_I

1. Specifications112345I-84TC : Total Cooling Capacity (kW)SHC : Sensible Heat Capacity (kW)CI : Compressor Input (kW)Rating conditions are: Outdoor A

Pagina 170

1. Specifications12345I-89SM830080● Heating Capacity15˚C20˚C25˚C1401201008060%25˚C20˚C15˚C1401201008060%–15 –10 –5 0 5 10 15Comp. motor power input ra

Pagina 171

1. Specifications112345I-901-8 Noise Criterion Curves4-Way Air Discharge Semi-concealed TypeMODEL : ASR 425 HSOUND LEVEL : HIGH 37 dB(A), NC 30LOW 31

Pagina 172

1. Specifications12345I-911-8 Noise Criterion CurvesCeiling Mounted TypeMODEL : ACR 425 HSOUND LEVEL : HIGH 39 dB(A), NC 34LOW 34 dB(A), NC 26CONDITIO

Pagina 173 - 0639_X_S

1. Specifications12345I-31-1 Unit Specifications4-Way Air Discharge Semi-concealed TypeMODEL No. Indoor Unit ASR 425 HOutdoor Unit AER 425 SCL3EPO

Pagina 174 - 0641_X_S

1. Specifications112345I-921-8 Noise Criterion CurvesConcealed Duct TypeMODEL : ADR 425 HSOUND LEVEL :HIGH 34 dB(A), NC 22 / LOW 27 dB(A), NC 18CONDIT

Pagina 175 - Multimeter

1. Specifications112345I-94MODEL : AER 425 SCLE - AER 425 SCL3EAER 425 SHLE - AER 425 SHL3ESOUND LEVEL : 52 dB(A), NC 44CONDITION : Distance 1m, Heigh

Pagina 176 - 0643_X_S

1. Specifications12345I-951-9 Indoor Fan PerformanceConcealed Duct TypeIf external static pressure is too great (due to longextension of ducts, for ex

Pagina 177

1. Specifications12345I-971-10 Air throw Distance Chart4-Way Air Discharge Semi-concealed TypeModel: 25 TypeModel: 36, 48 Type012345601234HORIZONTAL D

Pagina 178 - Outdoor P.C.B. Ass’y

1. Specifications112345I-981-10 Air throw Distance ChartCeiling Mounted Type012345678910012345HORIZONTAL DISTANCE (m)AXIS AIR VELOCITY (m/s)VERTICAL D

Pagina 179 - 1250_X_I

1. Specifications12345I-991-11 Installation InstructionsTubing Length(A) Single type● Refrigerant tubing between the indoor andoutdoor units should be

Pagina 180 - • ACR 425 H

1. Specifications112345I - 100SM830080NOTE Indoor UnitAVOID:● areas where leakage of flammable gas may beexpected.● places where large amounts of oil

Pagina 181 - • ADR 448 H

1. Specifications12345I - 101 Outdoor UnitAVOID:● heat sources, exhaust fans, etc. (Fig. 1-3)● damp, humid or uneven locations.DO:● choose a place as

Pagina 182 - Outdoor Units

1. Specifications112345I - 102 Air Discharge Chamber for Top DischargeBe sure to install the air discharge chamber in the filedwhen:● it is difficult

Pagina 183 - • AER 448 SHL3E

1. Specifications12345I - 1031-11 Installation InstructionsSelecting the Installation Site Wind Shield It is recommended to install wind shields for

Pagina 184 - Temperature (°C)

1. Specifications112345I-41-1 Unit Specifications4-Way Air Discharge Semi-concealed TypeMODEL No. Indoor Unit ASR 436 HOutdoor Unit AER 436 SCL3EP

Pagina 185

1. Specifications112345I - 104 General Precautions on Wiring(1) Before wiring, confirm the rated voltage of the unitas shown on its nameplate, then c

Pagina 186

1. Specifications12345I - 105SM8300801-11 Installation Instructions Electrical Wiring• Indoor Unit(F) Power SupplyPower Supply Terminal BaseCapacity

Pagina 187

1. Specifications112345I - 106● Wiring System Diagrams(1) Basic wiring diagram for standard control1 Single type (one indoor unit)1-1. 3-phase outdoor

Pagina 188 - 1577_C_I

1. Specifications12345I - 1071-11 Installation Instructions Electrical CharacteristicsIndoor Unit : ASR 425 H Outdoor Unit : AER 425 SCLEA

Pagina 189 - 1579_M_I

1. Specifications112345I - 1081-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ASR 425 H Outdoor Unit : AER

Pagina 190 - 5. Appendix

1. Specifications12345I - 1091-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ASR 436 H Outdoor Unit : AER 436 SCL3E

Pagina 191 - 5-1 P.C.B

1. Specifications112345I - 1101-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ASR 448 H Outdoor Unit : AER 448 SCL3EA

Pagina 192

1. Specifications12345I - 1111-11 Installation InstructionsElectrical CharacteristicsIndoor Unit: ACR 425 H Outdoor Unit : AER

Pagina 193

1. Specifications112345I - 1121-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ACR 425 H Outdoor Unit : AER

Pagina 194

1. Specifications12345I - 1131-11 Installation InstructionsElectrical CharacteristicsIndoor Unit : ACR 436 H Outdoor Unit : AER 436 SCL3EAE

Commenti su questo manuale

Nessun commento