IQ-400 - Series Intelligent Access Control SystemsInstallation Manual33-10057-001REV: CPCSC3541 Challenger StreetTorrance, CA 90503Phone: (310) 303-36
...Expansion Board Door Lock/Strike xxxvii...
9.1.3 Spare Parts- IQ-400 PCBPart Number Description Designation 81-09009 3V Lithium Battery BT178-01001 4A 250V 1/4 x 1/4,
9.2 IQ 4-Reader Expansion Module (P/N: 03-10102-301E)The IQ-400 4-reader system can be expanded to an 8-reader system by installing the 4-Reader Expan
9.2.3 Door Sense LEDs4 LEDs located at D17, D18, D19, and D20 indicate the status of the Door circuits. Resistors must be installed at the door contac
9.2.5.1 Four-Reader Expansion Board (P/N: 03-10102-301E) - Jumper SelectionsThere are five jumper units located on the 4-Reader Expansion PCB circuit
9.3 IQ-800 Features (IQ-400 plus 4-Reader Expansion Module)9.3.1 Two Auxiliary (Powered) Outputs (cc# 89, 90)8 Reader Ports: (Wiegand electrical inter
9.3.4 Spare Parts- 4-Reader Expansion Board (P/N: 03-10102-301E)Part Number Description Designation 83-02082 5-pin Plug Connector P1
9.4 IQ 8-Reader Expansion Module (P/N: 03-10102-201E)The IQ-400 4-reader system can be expanded to a 12-reader system by installing the 8-Reader Expan
9.4.3 Door Sense LEDs8 LEDs located at D17, D18, D19, D20, D21, D22, D23, and D24 indicate the status of the Door circuits. Resistors must be installe
9.4.5.1 Eight-Reader Expansion Board (P/N: 03-10102-201E) - Jumper SelectionsThere are five jumper units located on the 8-Reader expansion PCB circuit
9.5 IQ-1200 Features (IQ-400 plus 8-Reader Expansion Module)2 Auxiliary (Powered) Outputs (cc# 89, 90)12 Reader Ports: (Wiegand electrical interface
and RX LEDs glow red to show activity on the data wires. The TX LED indicates the fiber modem is transmitting and the RX LED indicates reception of d
9.5.3 Spare Parts- 8-Reader Expansion Board (P/N: 03-10102-201F)Part Number Description Designation 83-02082 5-pin Plug Connector P2,
9.6 OUT PCB Features (P/N: 03-10032-201F)16 Form C Relay Dry Contact Outputs (2.0 amps @ 12/24 VDC continuous power)16 Unsupervised Sense Inputs (Alar
9.7 ALM PCB Features (P/N:P 03-10032-301)16 Unsupervised Sense Inputs (Alarm points 56-71)LEDs for: status, +5Vdc, +12Vdc9.7.1 System CapacitiesEnclo
9.8 SAM BoardLEDs for: status, +5Vdc, +12Vdc9.8.1 System CapacitiesEnclosure Dimensions: 18”H x 11.5”W x 6”D (45.7cm x 29.2cm x 15.2cm)Weight:
9.9 Cable Requirements and Maximum Lengths9.9.1 Communication-Type of Type of 22awg Maximum Distance Max. Distance w/PIN Pad Technology Stran
9.10 Tool RequirementsCable Connection ToolOn the IQ-200 circuit board, a standard screwdriver is required for securing cabling connections.9.11 Contr
Serial CommunicationTwo serial communication ports are provided by the IQ-400 controller.•RS-485: Four wire (twisted pair) interface which is opticall
9.12 Maintenance Requirements The following items require testing and/or maintenance to be performed on the SIM at least once a year. •Fuse Replacemen
10.0 Appendix B – Configuring the IQ-400E10.1 Configuring the IQ-400E for Version 0130 and aboveThe following Configuration Instructions are for updat
10.2 Configuring your Host Computer1. Change host IP to be 192.168.168.3 in your computer’s TCP/IP settings - This is the default Host IP address that
...8.9.2 Outputs lxxxiii...
10.3 Configuring IQ-400E VIA the TCP/IP ConfiguratorUse a Web Browser to configure and view the IQ-400E Configuration Information (IE 5 or greater, or
10.3.1 TCP/IP Configuration5. Change the appropriate values.a. Panel Number – This must match the IQ-400E panel number.b. Host IP – This is the LiNC
8. Click on the Update button. The following screen(s) will appear depending on the field you have changed. Page cix of 110 IQ-400 Installation Manua
9. Close the Browser. You will have to change your Host IP to match the Host IP address just entered in the TIP/IP Configuration10. Re-open the Browse
10.4 Resetting the IQ-400EIf the IQ-400E panel is accidentally set to an incorrect (and/or unknown) IP address, it is possible to reset the panel to i
End of ManualPCSC, Inc.August 2008 Page cxii of 110 IQ-400 Installation Manual 33-10057-001-C
...10.3.1 TCP/IP Configuration cviii...
1.0 IntroductionWelcome to the IQ-400, the newest generation of intelligent access control system from PCSC.This manual explains IQ-400 installation a
The LiNC-NET Network Controller communicates on a multi-point RS485 communication cable (RS-232, MODEM and LAN communication are also available). You
2.0 Unpacking the IQ-4002.1 Unpacking the IQ-400As you unpack the IQ-400, inspect it for missing items or damage. Contact the dealer for any irregular
5. Are the jumpers in place at W1, W2, W3, W4, and W8?•Jumper W8 is located in the LOWER LEFT side of the board and is set for 12 volt-4-wire, 12 volt
•Jumper W2 is located in the LOWER RIGHT side of the board, to the left of Plug P16 and is set for 4 or 5 wire readers. (Must be set consistently with
IQ-400 - Expansion Cable Plug•Is the 50-pin Expansion Bus Ribbon Cable connected to the IQ-400 at Plug J1? The RED stripe on the edge of the ribbon ca
First Edition: July 2006Revision B: May 2007Revision C: August 2008Information in this manual is subject to change without notice and does not repr
3.0 Installing Power3.1 Installing PowerShown below are the 3.0A and 6.0A PCSC power supplies. Both power supplies are shown in enclosures connected t
3.1.3 Figure - PCSC 3.0 Amp Power Supply Page viii of 110 IQ-400 Installation Manual 33-10057-001-C
3.1.4 Figure - PCSC 6.0 Amp Power Supply Page ix of 110 IQ-400 Installation Manual 33-10057-001-C
3.1.5 Resetting the IQ-400 to Default ValuesIn the event that the 3-volt watch battery is removed or loses its electrical charge, the IQ-400 must be r
4.0 Wiring Your Readers4.1 Grounding Your ReadersPCSC has designed its products to withstand most inductive voltage spikes without effect. However, s
4.3 Grounding the Power and Data LinesEach cable has a set of drain lines that can be attached on the Host or controller end of the cable to any screw
NOTE: The Small Enclosure that is described with Dimensions of 18”H x 6”D x 11”W has been previously Evaluated and Listed for use with UL 1076 and UL
4.3.2 Proper Surge Protection for the IQPage xiv of 110 IQ-400 Installation Manual 33-10057-001-C
4.4 Grounding the Pin Pad or Reader4.4.1 Procedure1. Orient the mounting plate so that the protruding ears are on top and facing the back of the reade
5.0 Reader Connections5.0.1. Reader Disconnect ResistorsIf an external power supply and a reader disconnect feature is required, place a 470 Ohm – 1 W
0.1 Board Diagrams0.1.1 The IQ-400 Printed Circuit Board Wiring DiagramNOTE: When communication via LAN, the PCB is referred to as an IQ400EPage iii
5.1 Reader Connections: BR-350 Readers: IQ-400 BoardPage xvii of 110 IQ-400 Installation Manual 33-10057-001-C
5.2 Reader Connections: BR-350 Readers: Expansion BoardPage xviii of 110 IQ-400 Installation Manual 33-10057-001-C
5.3 Reader Connections: BR-370 Readers: IQ-400 BoardPage xix of 110 IQ-400 Installation Manual 33-10057-001-C
5.4 Reader Connections: BR-370 Readers: Expansion BoardPage xx of 110 IQ-400 Installation Manual 33-10057-001-C
5.5 Reader Connections: PR233 MiniProx / PR-733/732: IQ-400 Board - Option 1Page xxi of 110 IQ-400 Installation Manual 33-10057-001-C
5.5 Reader Connections: PR233 MiniProx / PR-733/732: IQ-400 Board - Option 2Page xxii of 110 IQ-400 Installation Manual 33-10057-001-C
5.6 Reader Connections: PR-233 Miniprox/ PR733/ 732: Expansion Board – Option 1Page xxiii of 110 IQ-400 Installation Manual 33-10057-001-C
5.6 Reader Connections: PR-233 Miniprox / PR733 / 732: Expansion Board – Option 2Page xxiv of 110 IQ-400 Installation Manual 33-10057-001-C
5.7 Reader Connections: PR-234 / PRK-234 ProxPro / PR736 / PRK-736: IQ-400 BoardPage xxv of 110 IQ-400 Installation Manual 33-10057-001-C
5.8 Reader Connections: PR-234 / PRK-234 ProxPro / PR736/ PRK-736: Expansion BoardPage xxvi of 110 IQ-400 Installation Manual 33-10057-001-C
0.1.2 Four-Door Expansion BoardPage iv of 110 IQ-400 Installation Manual 33-10057-001-C
5.9 Reader Connections: PR-235 MaxiProx / PR-735: IQ-400 BoardPage xxvii of 110 IQ-400 Installation Manual 33-10057-001-C
5.10 Reader Connections: PR-235 MaxiProx / PR735: Expansion BoardPage xxviii of 110 IQ-400 Installation Manual 33-10057-001-C
5.11 Reader Connections: Sensor Wiegand: IQ-400 BoardPage xxix of 110 IQ-400 Installation Manual 33-10057-001-C
5.12 Reader Connections: Sensor Wiegand: Expansion BoardPage xxx of 110 IQ-400 Installation Manual 33-10057-001-C
5.13 Reader Connections: VeriProx: IQ-400 BoardPage xxxi of 110 IQ-400 Installation Manual 33-10057-001-C
5.14 Reader Connections: VeriProx: Expansion BoardPage xxxii of 110 IQ-400 Installation Manual 33-10057-001-C
6.0 Wiring the Door(s)Step 1. When power is interrupted from the IQ-400, the door relay de-energizes and continuity (conduction path) exists between
Step 4. Program the quiescent (INACTIVE) state of the door output relay to provide a locked door state. For Fail-Safe environments, the quiescent sta
6.1 Panel in a Fail-Safe EnvironmentPage xxxv of 110 IQ-400 Installation Manual 33-10057-001-C
6.2 Panel in a Fail-Secure EnvironmentPage xxxvi of 110 IQ-400 Installation Manual 33-10057-001-C
0.1.3 Eight-Door Expansion Board Page v of 110 IQ-400 Installation Manual 33-10057-001-C
6.3 Expansion Board Door Lock/StrikePage xxxvii of 110 IQ-400 Installation Manual 33-10057-001-C
6.4 Expansion Board Open CollectorPage xxxviii of 110 IQ-400 Installation Manual 33-10057-001-C
6.5 Egress Sense for IQ-400 and Expansion BoardsPage xxxix of 110 IQ-400 Installation Manual 33-10057-001-C
6.6 Door Sense for IQ-400 and Expansion BoardsPage xl of 110 IQ-400 Installation Manual 33-10057-001-CNOTE For UL Installations, the maximum number
6.6.1 Using the Ten Discrete LEDsTwenty-two LED’s, located across the lower section of the IQ-400 board, indicate the status of the supervised door ci
6.6.2 Expansion Board LED Arrays4-Door Expansion Board (IQ-800) 8-Door Expansion Board (IQ-1200)NOTE: Numbers in parentheses are the Sense Input N
6.6.3 SAM Board LED Arrays6.6.4 Status Chart For All LED ArraysOFF Circuit is normal/secureON Circuit is in an alarm conditionFlashes
6.7 Supervised Sense Inputs for P5, P6 and P19 and Unsupervised Tamper at P18Page xliv of 110 IQ-400 Installation Manual 33-10057-001-C
Page xlv of 110 IQ-400 Installation Manual 33-10057-001-C
6.8 Expansion Board Supervised Door Senses and Supervised Request-to-Exit Sense Inputs Page xlvi of 110 IQ-400 Installation Manual 33-10057-001-CIns
0.1.4 OUT Expansion BoardPage vi of 110 IQ-400 Installation Manual 33-10057-001-C
6.9 Expansion Board Supervised Door Sense LocationsPage xlvii of 110 IQ-400 Installation Manual 33-10057-001-CInstall End-of-Line resistors at door
6.10 Installing Noise Suppression DevicesInstall an MOV or diode (or both) at the lock to suppress noise and avoid problems related to spikes. Follow
7.0 Communicating with the IQ-400The IQ-400 can communicate over a dialup MODEM, an RS232 or an RS485 serial direct connection or LAN. In a multi-drop
7.2 Calibrating the IQ-400 PanelCalibration Scan Please check the LiNC-NET Calibrations Options page in the LiNC-NET Administrator Manual. 7.2.1 Cali
7.3 Addressing Individual IQ-400s through the Dipswitch7.3.1 Dipswitching the IQ-400 Address (1-111)The dipswitch is located at SW1, on the right-side
7.3.2 Software Addressing the IQ-400 Panel (Panels 112-200) Direct ConnectIf a user set up includes more than 111 panels, it is necessary to address t
7.4 Setting MODEM or Direct Connect ConfigurationsPCSC supports the US Robotics 33.6/56K Sportster model for MODEM communication. It is recommended th
7.4.1 Ensuring Proper Configuration of the MODEM To ensure that the MODEM retains the set configuration, the user should utilize HyperTerminal at the
7.4.2 Establishing a Proper Connection with a MODEM CableTo communicate from an IQ-400 to a MODEM, two cables must be fabricated: one from the MODEM t
7.5 Changing the Baud Rate1. Request the IQ-400 off-line in the Define Panel Online Status screen in the LiNC-NET software.2. Change the baud rate in
0.1.5 ALM Expansion BoardPage vii of 110 IQ-400 Installation Manual 33-10057-001-C
Page lvii of 110 IQ-400 Installation Manual 33-10057-001-C
7.6 Direct Connecting with One IQ-400The PC Host is connected to the IQ-400 by means of a cable designed for either RS-485 or RS-232 communication. Th
Page lix of 110 IQ-400 Installation Manual 33-10057-001-CIQ-400 to PC, RS-485 w/ DB25 Connector, Optically Isolated,PCSC P/N 04-10322-101IQ-400 to P
7.6.1 Wiring Diagram- IQ-400 to PC, RS-232 w/DB9 ConnectorPCSC P/N: 04-10318-1017.6.2 Wiring Diagram – IQ 400 to PC, RS -232 w/ DB25 ConnectorPCSC P/N
7.7 RS-232 Cable Connections NOTE: For UL 1076 requirements, the RS-232 cable shall not extend beyond 20 ft., and the cable shall stay within the sam
7.8 Communicating with Multiple IQ-400s (via RS-485)Once the PC host is connected to one IQ-400, the next IQ-400 can be connected by wiring from P3 fr
7.9 Real Time Serial Printing with the IQ-400To print from an IQ-400, a cable must be fabricated: a 9-pin female connector at the IQ-400-end to either
7.10 PC Host to IQ-400 Communication Using Fiber Optics (RS-485 Protocol)PCSC has tested two fiber optics systems for communication between the PC hos
7.10.2 InstallationTo install the MX-485-2, it is necessary to mount the unit to a rigid service using #8 hardware in four places. Care should be tak
7.10.2.2 PC Host to Multiple IQ-400s Using Fiber Optics Repeater Modules (RS-485 Protocol)American Fibertek’s MX-485-2 can be used as 2-port module (R
0.1.6 SAM BoardPage viii of 110 IQ-400 Installation Manual 33-10057-001-C
7.10.3 Optical TransmissionThe 485-2 series has been designed to be a reliable link for the transmission of data over long distances. The loss budget
8.0 Status Lights and Dealing with Communication Errors8.1 Status LightsThe IQ-400 circuit board has multiple LEDs. The status of the LED defines a ce
8.2 Communication ErrorsMessage at the PC What to Do IQ-400 is not responsive Verify the following:1. The red DC Power Indicator LED (D2)
8.2.2 Error CodesThe seven-segment LEDs, D49 and D50, will indicate certain errors that can occur when processing cards. They also can communicate “fa
8.3 Control Counters and Sense Input Numbers for Output Control PCBPage lxxi of 110 IQ-400 Installation Manual 33-10057-001-C
Page lxxii of 110 IQ-400 Installation Manual 33-10057-001-C
8.4 Proper Setting of SAM 1 and SAM 2In a system that uses SAM 1 as a stand-alone, the W1 switch must be set to LOW (Pins 2-3).In a system that uses b
8.5 IQ Systems Upgrades and CapacitiesModelReadersSupervised Reader DetectDoor Relay OutputsAuxiliary Relay OutputsExternal Shunt/Local Alarm Transist
8.6 RS-232/485 Terminal Servers8.6.1 IQ Server Controller to LANtronix UDS-1100 Terminal Server Wiring Diagram for RS-232The cable between the UDS-110
8.6.3 IQ Server Controller to the EasySync USB ConverterPage lxxvi of 110 IQ-400 Installation Manual 33-10057-001-C
0.2 Table of Contents...1.0 Introduction 1...
8.7 RS-232-485/422 Converters: Printed Circuit Board Layout Page lxxvii of 110 IQ-400 Installation Manual 33-10057-001-C
8.8 User Selectable OptionsUnderlined settings are for LiNC-NET User -Selectable Options.An asterisk (*) designates the factory preset jumper settings
ONONONLine Bias On (The Carrier Detect light will come on. Default is +5 volts.)Line Bias On (The Carrier Detect light will come on. Default is +5 v
IQ SAM/1st SAM Board (P/N 03-10056-201)Designation LocationS40 P2, pin 1, 2, S41 P2, pin 3, 4S42 P3, pin 1, 2S43 P3, pin 3, 4S44 P4, p
8.9.1.2 IQ-800 Series Point Definitions – Sense InputsPage lxxxi of 110 IQ-400 Installation Manual 33-10057-001-CS3 through S6 are located on the IQ
8.9.1.3 IQ-1200 Series Point Definitions – Sense InputsPage lxxxii of 110 IQ-400 Installation Manual 33-10057-001-CS3 through S10 are located on the
8.9.2 Outputs8.9.2.1 IQ-400 Series Point Definitions – Outputs Page lxxxiii of 110 IQ-400 Installation Manual 33-10057-001-CIQ-400 (P/N: 03-10111-20
8.9.2.2 IQ-800 Series Point Definitions – Outputs Page lxxxiv of 110 IQ-400 Installation Manual 33-10057-001-C4-Reader Expansion PCB (P/N: 03-10102-
8.9.2.3 IQ-1200 Series Point Definitions – Outputs Page lxxxv of 110 IQ-400 Installation Manual 33-10057-001-C8-Reader Expansion PCB (P/N: 03-10102-
9.0 Appendix A - IQ-400 Specifications9.1 IQ-400 Features2 Auxiliary Powered Outputs (cc# 89, 90)1 Unsupervised Tamper Sense Input (S13)4 Reader Ports