AR-BC320 TROUBLESHOOTING 11 - 12
Main
code
Sub
code
Title
Toner empty sensor abnormality
(Magenta)
F2 42 Display Lamp/Message
Phenomenon Detail Toner empty sensor output
abnormality
Section Cartridge
Case 1 Cause Connector harness
trouble, connector
disconnection
Check &
Remedy
1. Check connection of the
toner empty sensor.
Connect it properly.
2. Check connection of the
connector harness to
the PCU PWB.
Connect it properly.
3. Check connection of the
cartridge.
Connect it
properly.
4. Check for disconnection
of the harness.
Replace the harness.
Case 2 Cause Cartridge trouble
Check &
Remedy
Replace the cartridge.
Main
code
Sub
code
Title
Toner empty sensor abnormality
(Yellow)
F2 43 Display Lamp/Message
Phenomenon Detail Toner empty sensor output
abnormality
Section Cartridge
Case 1 Cause Connector harness
trouble, connector
disconnection
Check &
Remedy
1. Check connection of the
toner empty sensor.
Connect it properly.
2. Check connection of the
connector harness to
the PCU PWB.
Connect it properly.
3. Check connection of the
cartridge.
Connect it
properly.
4.
Check for disconnection
of the harness.
Replace the harness.
Case 2 Cause Cartridge trouble
Check &
Remedy
Replace the cartridge.
Main
code
Sub
code
Title
Black image density sensor
trouble (Transfer belt surface
reflection ratio abnormality)
F2 44 Display Lamp/Message
Phenomenon Detail Before starting process
control, the transfer belt
surface is scanned with the
image density sensor to
adjust the sensor gain so
that the output becomes a
fixed value. However,
when the sensor gain is
changed, the output is not
within the specified range.
Section
Common Check Use SIM 44-2 to adjust the
process control sensor
gain.
Case 1 Cause When "Error" occurs in
SIM 44-2:
1. Dirt/defect of the image
density sensor
2. Disconnection of the
harness between the
PCU PWB and the
image density sensor
3. Calibration plate
solenoid operation
trouble
Check &
Remedy
1. Clean/replace the
image density sensor.
2. Connect/replace the
harness between the
PCU PWB and the
image density sensor.
3. Replace the calibration
plate solenoid.
Case 2 Cause When SIM 44-2 is
completed:
1. Insufficient cleaning of
the transfer belt.
Check &
Remedy
1. Check the transfer belt
surface.
Main
code
Sub
code
Title
Color image density sensor
trouble (Calibration plate surface
reflection ratio abnormality)
F2 45 Display Lamp/Message
Phenomenon Detail Before starting process
control, the calibration
plate surface is scanned
with the image density
sensor to adjust the sensor
gain so that the output
becomes a fixed value.
However, when the sensor
gain is changed, the output
is not within the specified
range.
Section
Common Check Use SIM 44-2 to adjust the
process control sensor
gain.