5. PARAMETERS
5 - 25
No. Symbol Name and function
Initial
value
(unit)
Setting
range
PB23 VFBF Low-pass filter selection
Select the shaft resonance suppression filter and low-pass filter.
Refer to Name
and function
column.
Setting
digit
Explanation
Initial
value
_ _ _ x Shaft resonance suppression filter selection
0: Automatic setting
1: Manual setting
2: Disabled
When you select "Enabled (_ _ _ 1)" of "Machine
resonance suppression filter 4 selection" in [Pr. PB49], the
shaft resonance suppression filter is not available.
0h
_ _ x _ Low-pass filter selection
0: Automatic setting
1: Manual setting
2: Disabled
0h
_ x _ _ For manufacturer setting 0h
x _ _ _ 0h
PB24
MVS
Slight vibration suppression control
Select the slight vibration suppression control and PI-PID switching control.
Refer to Name
and function
column.
Setting
digit
Explanation
Initial
value
_ _ _ x Slight vibration suppression control selection
0: Disabled
1: Enabled
To enable the slight vibration suppression control, select
"Manual mode (_ _ _ 3)" of "Gain adjustment mode
selection" in [Pr. PA08]. Slight vibration suppression control
cannot be used in the speed control mode.
0h
_ _ x _ PI-PID switching control selection
0: PI control enabled
(Switching to PID control is possible with commands of
controller.)
3: Continuous PID control enabled
0h
_ x _ _ For manufacturer setting 0h
x _ _ _ 0h