5. PARAMETERS
5 - 34
No. Symbol Name and function
Initial
value
(unit)
Setting
range
PC04

COP1
Function selection C-1
Select the encoder cable communication method selection.
Refer to Name
and function
column.
Setting
digit
Explanation
Initial
value
_ _ _ x For manufacturer setting 0h
_ _ x _ 0h
_ x _ _ 0h
x _ _ _ Encoder cable communication method selection
0: Two-wire type
1: Four-wire type
Incorrect setting will result in [AL. 16 Encoder initial communication
error 1].
0h
PC05

COP2
Function selection C-2
This is used to select the motor-less operation.
Refer to Name
and function
column.
Setting
digit
Explanation
Initial
value
_ _ _ x Motor-less operation selection
0: Disabled
1: Enabled
0h
_ _ x _ For manufacturer setting 0h
_ x _ _ 0h
x _ _ _ 0h
PC06
COP3
Function selection C-3
Select the error excessive alarm level setting for [Pr. PC01]. The parameter is not available in
the speed control mode and torque control mode.
Refer to Name
and function
column.
Setting
digit
Explanation
Initial
value
_ _ _ x For manufacturer setting 0h
_ _ x _ 0h
_ x _ _ 0h
x _ _ _ Error excessive alarm level unit selection
0: Per rev or mm
1: Per 0.1 rev or 0.1 mm
2: Per 0.01 rev or 0.01 mm
3: Per 0.001 rev or 0.001 mm
0h
PC07 ZSP Zero speed
Used to set the output range of ZSP (Zero speed detection).
ZSP (Zero speed detection) has hysteresis of 20 r/min or 20 mm/s.
50
[r/min]/
[mm/s]
0 to
10000
PC08 OSL Overspeed alarm detection level
This is used to set an overspeed alarm detection level.
When you set a value more than "(linear) servo motor maximum speed × 120%", the set value
will be clamped.
When you set "0", the value of "(linear) servo motor maximum speed × 120%" will be set.
0
[r/min]/
[mm/s]
0 to
20000