11. Options and peripheral devices
11 - 37
2-d mounting hole
(Varnish is removed from right mounting
hole (face and back side).) (Note 1)
W ± 2
W1
H
Max. D
PP1
Fig. 11.1
4-d mounting hole
(Varnish is removed from front right mounting
hole (face and back side).) (Note 1)
W ± 2
W1
H
D1
D3
Max. D
D2
PP1
Fig. 11.2
(Note 2)
Servo amplifier
P3
P4
FR-HEL
5 m or less
Note 1. Use this hole for grounding.
2. When using the Power factor improving DC reactor, remove the short bar across P3-P4.
Dimensions [mm]
Servo amplifier
Power factor
improving DC
reactor
Reference
W W1 H
D
(Note 1)
D1 D2 D3 d
Terminal
screw
size
Mass
[kg]
Wire [mm
2
]
(Note 2)
MR-J4-10B/MR-
J4-20B
FR-HEL-0.4K 70 60 71 61 21 M4 M4 0.4
MR-J4-40B FR-HEL-0.75K 85 74 81 61 21 M4 M4 0.5
MR-J4-60B/MR-
J4-70B
FR-HEL-1.5K 85 74 81 70 30 M4 M4 0.8
MR-J4-100B FR-HEL-2.2K
Fig. 11.1
85 74 81 70
30
M4 M4 0.9
MR-J4-200B FR-HEL-3.7K 77 55 92 82 66 57 37 M4 M4 1.5
2 (AWG 14)
MR-J4-350B FR-HEL-7.5K 86 60 113 98 81 72 43 M4 M5 2.5 3.5 (AWG 12)
MR-J4-500B FR-HEL-11K
Fig. 11.2
105 64 133 112 92 79 47 M6 M6 3.3 5.5 (AWG 10)
MR-J4-700B FR-HEL-15K 105 64 133 115 97 84 48.5 M6 M6 4.1 8 (AWG 8)
Note 1. Maximum dimensions (The dimension varies depending on the bending degree of the input/output line.)
2. Selection condition of wire size is as follows.
Wire type: 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: One wire is constructed in the air