11. Options and peripheral devices
11 - 27
When using the FR-CV, always install the dedicated stand-alone reactor (FR-CVL).
Power regenerative common
converter
Dedicated stand-alone
reactor
FR-CV-7.5K(-AT) FR-CVL-7.5K
FR-CV-11K(-AT) FR-CVL-11K
FR-CV-15K(-AT) FR-CVL-15K
FR-CV-22K(-AT) FR-CVL-22K
FR-CV-30K(-AT) FR-CVL-30K
FR-CV-37K FR-CVL-37K
FR-CV-55K FR-CVL-55K
(3) Connection diagram
POINT
In this configuration, only the STO function is supported. The forced stop
deceleration function is not available.
MC
MCCB
R/L11
3-phase
200 to
230 V AC
S/L21
T/L31
S2/L22
R2/L12
T2/L32
FR-CVL
MC
RA1
EM1
OFF
ON
RESET
(Note 1)
MC
SK
DOCOM
RA1
EM1
R2/L1
S2/L2
N/L-
(Note 2)
P24
SD
RDYB
RDYA
RSO
SE
SD
P/L+
T2/L3
R/L11
S/L21
T/MC1
RES
(Note 1)
L11
L21
P+
N-
U
V
W
(Note 1)
(Note 6)
EM1
U
V
W
CN2
FR-CV
Servo motor
Servo amplifier
(Note 3)
Servo system
controller
(Note 4)
(Note 5)
(Note 7)
DICOM
24 V DC
B
C
A
RA1
Note 1. Configure a sequence that will shut off main circuit power at the follow cases.
FR-CV or servo amplifier alarm occurs.
EM1 (forced stop 1) turns off.
2. For the servo amplifier, configure a sequence that will switch the servo-on after the FR-CV is ready.
3. For the FR-CV, the RSO signal turns off when it is put in a ready-to-operate status where the reset signal is input.
Configure a sequence that will make the servo inoperative when the RSO signal is on.
4. Configure a sequence that will make a stop with the emergency stop input of the servo system controller if an alarm
occurs in the FR-CV. When the servo system controller does not have an emergency stop input, use the forced stop
input of the servo amplifier to make a stop as shown in the diagram.
5. When using the servo amplifier of 7 kW or less, make sure to disconnect the wiring of built-in regenerative resistor (5 kW
or less: P+ and D, 7 kW: P+ and C).
6. Set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop 1).
7. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded case circuit breaker.
P4
When using the FR-CV, disconnect between P3 and P4 terminals.
6. Set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop 1).
7. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded case circuit breaker.